Genuine OEM replacement motors for the ICP/Heil/Tempstar WPG4424060LKB1 packaged unit, covering both the 1/2 HP blower motor (PN 1188130) and the 1/5 HP, 810 RPM condenser fan motor (PN 1186359). The blower motor circulates conditioned air through the duct system, while the condenser fan motor pulls air across the outdoor coil to reject heat. Motors fail from worn bearings, open windings, or a seized shaft — symptoms include loud humming, overheating, intermittent operation, or no airflow at all. Installing the correct OEM-spec motor restores proper airflow, efficiency, and compressor protection.

Specifications

Spec Value
Part Numbers 1188130 (Blower 1/2 HP), 1186359 (Condenser 1/5 HP)
Type Blower Motor & Condenser Fan Motor
Brand ICP / Heil / Tempstar
Horsepower 1/2 HP (blower), 1/5 HP (condenser)
Condenser RPM 810
Fits Model WPG4424060LKB1

Compatibility

Direct OEM replacement for the ICP, Heil, Comfortmaker, and Tempstar WPG4424060LKB1 packaged gas/electric unit. The 1/2 HP blower and 1/5 HP 810 RPM condenser fan motors are also used across comparable ICP-family packaged systems. Verify horsepower, rotation, voltage, and shaft diameter against your failed motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the blower or condenser access panel as applicable.
  3. Document — Photograph all motor wiring, capacitor leads, and the blade/wheel position on the shaft.
  4. Remove — Loosen the blade or blower wheel set screw, disconnect the wires, and unbolt the motor from its mount or bracket.
  5. Install — Mount the new motor, set the blade/wheel to the original depth, and reconnect wiring and capacitor per your photo.
  6. Test — Restore power, start the system, and confirm smooth rotation, correct direction, and full airflow.

Signs You Need a Replacement

  • Loud humming or grinding with little or no airflow.
  • Motor runs hot and trips on its internal overload.
  • Shaft is stiff, seized, or wobbles with bearing play.
  • Fan won't start without a manual spin, or stops intermittently.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4424060LKB1 — 1/2 HP & 1/5 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4424060LKB1 — 1/2 HP & 1/5 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4424060LKB1 — 1/2 HP & 1/5 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.