OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 40VA control transformer (part #97298) steps the WUGD175CK01's 120V line voltage down to 24V to power the thermostat circuit, gas valve, and relays. The kit also includes the OEM 24V SPDT relay (part #92840) used in this model's control sequence. A failed transformer kills the entire low-voltage control system — the furnace stops responding to the thermostat, the blower won't run on a call for heat, and ignition never starts. Buzzing, overheating, or a repeatedly blown control fuse all point to transformer failure.
| Spec | Value |
|---|---|
| Part Number | 97298 (trans), 92840 (relay) |
| Type | Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Rating | 40 VA |
| Primary Voltage | 120V |
| Secondary Voltage | 24V |
| Fitment | OEM |
Fits the ICP Tempstar Heil WUGD175CK01 gas furnace and other ICP-family units (Heil, Tempstar, Comfortmaker, Arcoaire) that use the same 40VA 120/24V control transformer and SPDT relay. Confirm primary voltage before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.