This OEM transformer supplies the 24-volt control power that runs the contactor coil, reversing-valve solenoid, and low-voltage relays on your ICP/Tempstar/Heil WPH3422000RKA1 heat pump. It steps the incoming line voltage down to a stable 24V, 40VA secondary output that energizes the entire control circuit. When a transformer fails, the system goes completely dead at the thermostat — no cooling, no heating, no contactor pull-in — even though high-voltage power is still present at the unit. A buzzing, scorched, or open-winding transformer is a common and inexpensive failure that mimics far more serious faults.

Specifications

Spec Value
OEM Part Numbers 1176148, 1172619, 1176137, 1172618
Type Control Transformer
Brand ICP / Tempstar / Heil
Secondary Voltage 24V
Rating 40VA
Fitment OEM Replacement

Compatibility

Engineered for the ICP WPH3422000RKA1 heat pump and shared across many Tempstar, Heil, and Comfortmaker units built on the same low-voltage control platform. Always confirm your secondary VA and voltage match before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the control-panel service cover.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Disconnect the line-voltage primary leads and 24V secondary leads, then unbolt the failed transformer from the panel.
  5. Install — Mount the new transformer, reconnect primary and secondary wiring per your photo.
  6. Test — Restore power and confirm a steady 24V reading at the secondary terminals.

Signs You Need a Replacement

  • System is completely unresponsive at the thermostat
  • Contactor will not pull in despite a cooling call
  • Audible buzzing from the control transformer
  • No 24V reading across the secondary terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPH3422000RKA1 — 24V Control Circuit | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPH3422000RKA1 — 24V Control Circuit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPH3422000RKA1 — 24V Control Circuit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online