ICP 40VA Transformer for WPG4484130LKA1 — 208/230 to 24V OEM 1173691 | Ships Today
ICP

ICP 40VA Transformer for WPG4484130LKA1 — 208/230 to 24V OEM 1173691 | Ships Today

SKU: WPG4484130LKA1-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40VA control transformer (part 1173691, "TRANS 208/230>24 40VA") with its 24V barrier (part 1178431) steps the 208/230V line voltage down to the 24V control circuit on the ICP Tempstar Heil WPG4484130LKA1. Every low-voltage component — the thermostat, gas valve, relays, and control board logic — depends on clean 24VAC from this transformer. When it fails or shorts, the entire control circuit goes dead: no thermostat response, no ignition, and often a blown low-voltage fuse on the board. A correctly rated 40VA transformer restores stable control power without overloading.

Specifications

Spec Value
Part Numbers 1173691, 1178431
Type Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V
Application Low-Voltage Control Circuit

Compatibility

Built for the ICP / Tempstar / Heil WPG4484130LKA1 and other ICP-family units using the 1173691 transformer and 1178431 barrier. Confirm primary voltage tap and VA rating before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph the primary and secondary leads and the voltage tap in use.
  4. Remove — Disconnect all leads, unbolt the transformer and barrier from the mounting bracket.
  5. Install — Mount the new transformer, install the 24V barrier, and reconnect leads to the matching primary tap and 24V secondary.
  6. Test — Restore power and confirm 24VAC at the secondary and normal thermostat operation.

Signs You Need a Replacement

  • No 24V control power; thermostat and system are unresponsive.
  • Repeatedly blown low-voltage control fuse.
  • Transformer is buzzing, overheated, or has a burnt smell.
  • Measured secondary voltage is missing or far below 24VAC.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG4484130LKA1 — 208/230 to 24V OEM 1173691 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG4484130LKA1 — 208/230 to 24V OEM 1173691 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG4484130LKA1 — 208/230 to 24V OEM 1173691 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.