Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WPG4304060RKB1 — 208/230 to 24V OEM 1173691 | Ships Today
ICP

ICP 40VA Transformer for WPG4304060RKB1 — 208/230 to 24V OEM 1173691 | Ships Today

SKU: 1178431-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40VA control transformer (part 1173691, with 24V barrier 1178431) is the direct-fit step-down transformer for the ICP/Tempstar/Heil WPG4304060RKB1 packaged unit. It converts incoming 208/230V line power down to the 24V control voltage that powers the thermostat, control board, gas valve, and contactor coil. When the transformer fails or shorts, the entire low-voltage control circuit goes dead. Symptoms include a blank thermostat, no response on a call for heat or cool, and a blown low-voltage fuse on the control board.

Specifications

Spec Value
Part Numbers 1173691, 1178431
Type Step-Down Control Transformer
Rating 40 VA
Voltage 208/230V Primary → 24V Secondary
Brand ICP / Tempstar / Heil
Fits Model WPG4304060RKB1
Fitment OEM Direct Replacement

Compatibility

Engineered as a factory replacement for the ICP/Tempstar/Heil WPG4304060RKB1 packaged system. Verify primary/secondary voltages and VA rating against parts 1173691 / 1178431 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/service panel.
  3. Document — Photograph the primary and secondary wiring before disconnecting.
  4. Remove — Label and disconnect the leads, then unbolt the old transformer.
  5. Install — Mount the new transformer, match the primary taps to your supply voltage, and reconnect per your photo.
  6. Test — Restore power and confirm 24V at the secondary and normal control operation.

Signs You Need a Replacement

  • Blank or unresponsive thermostat.
  • No 24V control voltage measured at the board.
  • Repeatedly blown low-voltage control fuse.
  • System won't respond to any call for heat or cool.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG4304060RKB1 — 208/230 to 24V OEM 1173691 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG4304060RKB1 — 208/230 to 24V OEM 1173691 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG4304060RKB1 — 208/230 to 24V OEM 1173691 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.