OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 40VA control transformer (ICP part #1173691, supplied with terminal barrier #1178431) steps the 208/230V line voltage down to the 24V control voltage that powers the thermostat, control board, gas valve, contactor coil, and safety circuits in ICP, Heil, Tempstar, and Comfortmaker WPG-series packaged units. A 40VA rating provides enough secondary current to drive the full low-voltage control load with margin. When a transformer fails — typically from a shorted secondary, an overloaded control circuit, or a power surge — the entire 24V system goes dead: no thermostat display, no inducer, no ignition, and no cooling call. The included 24V barrier protects the wiring connections and keeps the low-voltage leads organized and insulated at the transformer.
| Spec | Value |
|---|---|
| Part Numbers | 1173691 (transformer), 1178431 (24V barrier) |
| Type | Step-Down Control Transformer |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Rating | 40 VA |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| Fitment | OEM replacement |
Direct OEM replacement for the ICP/Tempstar/Heil WPG4244040RKA1 packaged gas/electric unit and other WPG-series cabinets using a 40VA 208/230-to-24V control transformer. Verify your primary supply is 208/230V and the VA rating matches before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.