This OEM 40VA control transformer is the direct-fit step-down power supply for the ICP / Heil / Tempstar / Comfortmaker WPG4244040LKA1 furnace. It converts the 208/230V line input to the 24V secondary that powers the control board, thermostat, gas valve, and relays. Covered OEM part numbers: 1173691 (Trans 208/230>24 40VA) and 1178431 (Barrier 24V). When a transformer fails — from a shorted secondary, an overloaded VA draw, or a power surge — the entire 24V control circuit goes dead, leaving the furnace completely unresponsive with a blank board and no thermostat call. This direct replacement restores stable 24V control power.

Specifications

Spec Value
Part Numbers 1173691, 1178431
Type Step-Down Control Transformer
Brand ICP / Heil / Tempstar / Comfortmaker
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V

Compatibility

Built for the WPG4244040LKA1 and used across matching ICP-built furnaces sold under the Heil, Tempstar, Comfortmaker, and Arcoaire names. Confirm the VA rating and primary/secondary voltages against the failed transformer before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph the primary and secondary leads and their terminal positions before disconnecting.
  4. Remove — Disconnect the leads, remove the mounting screws, and lift out the old transformer.
  5. Install — Mount the new transformer and reconnect primary and secondary leads per your photo, observing the correct voltage tap.
  6. Test — Restore power, confirm 24V across the secondary with a meter, and verify the control board and thermostat respond.

Signs You Need a Replacement

  • Completely dead furnace — no control board lights, no thermostat response
  • No measurable 24V on the secondary terminals
  • Burnt smell, melted housing, or scorched windings
  • Repeated low-voltage fuse blowing on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG4244040LKA1 — OEM 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG4244040LKA1 — OEM 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG4244040LKA1 — OEM 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online