Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WPG3604090RKC1 — 208/230 to 24V Kit | Ships Today
ICP

ICP 40VA Transformer for WPG3604090RKC1 — 208/230 to 24V Kit | Ships Today

SKU: 1178431-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM transformer kit for the ICP / Tempstar / Heil WPG3604090RKC1 packaged unit includes the 40VA step-down transformer (part 1173691) and its 24V terminal barrier (part 1178431). The transformer converts the 208/230V line supply down to the 24V control voltage that powers the thermostat, control board, gas valve, contactor coil, and pressure switch circuit. At 40VA it provides ample low-voltage capacity for the unit's full control load. The transformer is the heart of the control circuit — when it fails, the entire low-voltage side goes dead: no thermostat display, no relay pull-in, and neither heating nor cooling will operate. The included barrier keeps the 24V terminal connections organized and properly isolated.

Specifications

Spec Value
OEM Part Numbers 1173691 (Transformer), 1178431 (24V Barrier)
Type Step-Down Control Transformer
Brand ICP (Tempstar / Heil / Comfortmaker)
Rating 40 VA
Primary Voltage 208 / 230V
Secondary Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WPG3604090RKC1 packaged gas-electric unit and compatible ICP-family equipment using the 40VA 208/230-to-24V transformer 1173691 with barrier 1178431. Confirm the primary voltage tap and VA rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control access panel.
  3. Document — Photograph the primary (line) and secondary (24V) wiring and the barrier layout before removal.
  4. Remove — Label and disconnect the primary and secondary leads, then unmount the old transformer and barrier.
  5. Install — Mount the new transformer and barrier, wire the correct primary tap (208 or 230V), and connect the 24V secondary per your photo.
  6. Test — Restore power and confirm 24V across the secondary, then verify heating and cooling calls operate.

Signs You Need a Replacement

  • No 24V control voltage — thermostat is blank and nothing energizes.
  • Transformer is hot, buzzing, or has a burnt smell.
  • Repeated blown low-voltage fuses or a shorted secondary.
  • Open primary or secondary winding when measured with a meter.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3604090RKC1 — 208/230 to 24V Kit | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3604090RKC1 — 208/230 to 24V Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3604090RKC1 — 208/230 to 24V Kit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed