This OEM control transformer (part #1173691) steps 208/230V line voltage down to the 24V control voltage that powers the thermostat, contactor coil, and control board in your ICP, Tempstar, or Heil WPG3482115RKB1 unit. Rated at 40VA, it supplies the low-voltage circuit that runs the entire control system. A failed transformer means a completely dead control circuit — no thermostat response, no contactor pull-in, no operation at all. This listing includes the matching 24V barrier (#1176032) for a complete OEM replacement.

Specifications

Spec Value
Part Number 1173691 (transformer), 1176032 (24V barrier)
Type Control Transformer, Class 2
Brand ICP / Tempstar / Heil
Primary Voltage 208/230V
Secondary Voltage 24V
Rating 40VA

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPG3482115RKB1 package unit and other systems specifying a 208/230V-to-24V 40VA control transformer. Verify primary/secondary voltages and VA rating against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control box.
  3. Document — Photograph the primary (line) and secondary (24V) wiring before disconnecting.
  4. Remove — Label and disconnect the leads, then unfasten the old transformer and barrier from the control panel.
  5. Install — Mount the new transformer and 24V barrier, then reconnect primary and secondary wires per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals and normal control operation.

Signs You Need a Replacement

  • Dead control circuit — thermostat and system unresponsive
  • No 24V reading across the secondary terminals
  • Burned, melted, or smelling-hot transformer body
  • Repeated blown low-voltage fuses indicating a failed transformer

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3482115RKB1 — 208/230 to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3482115RKB1 — 208/230 to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3482115RKB1 — 208/230 to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.