Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WPG3424060LKC1 — 208/230V to 24V OEM | Ships Today
ICP

ICP 40VA Transformer for WPG3424060LKC1 — 208/230V to 24V OEM | Ships Today

SKU: 1178431-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This ICP 40VA control transformer (OEM #1173691) steps the line-voltage 208/230V supply down to the 24V control voltage used by the WPG3424060LKC1's thermostat, control board, gas valve, and contactor. It ships with the matching 24V barrier (OEM #1178431) used to isolate and protect the low-voltage terminals. Without a working transformer, the unit has no control power — the thermostat goes dark and nothing energizes. A blown or shorted transformer is a frequent culprit when a system is completely unresponsive despite having line power.

Specifications

Spec Value
Part Numbers 1173691 (Transformer), 1178431 (24V Barrier)
Type Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V
Fitment WPG3424060LKC1

Compatibility

Designed for the ICP / Tempstar / Heil WPG3424060LKC1 package gas/electric unit. The 208/230V primary and 40VA rating must match your existing transformer; the included 24V barrier (1178431) protects the secondary terminals per the factory layout.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect. Verify zero voltage with a multimeter on both primary and secondary.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph all primary and secondary leads and the barrier position before disconnecting.
  4. Remove — Disconnect the leads, remove the mounting screws, and lift out the old transformer and barrier.
  5. Install — Mount the new transformer, install the 24V barrier, and reconnect the primary (line) and secondary (24V) leads exactly per your photo.
  6. Test — Restore power and confirm 24V at the secondary and that the thermostat and controls power up.

Signs You Need a Replacement

  • Thermostat is blank and no controls respond despite line power present
  • No 24V measured at the secondary terminals
  • Visible burn marks, melted housing, or a burnt-electrical smell
  • Repeated control fuse or transformer failures from a downstream short

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPG3424060LKC1 — 208/230V to 24V OEM | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPG3424060LKC1 — 208/230V to 24V OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPG3424060LKC1 — 208/230V to 24V OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online