This genuine OEM control transformer (OEM 1173691) steps down 208/230V line voltage to the 24V needed to power the thermostat, contactor coil, and low-voltage control circuit on the ICP / Tempstar / Heil WPA3364000RKC1 heat pump. Rated at 40VA, it supplies stable control power to every 24V component in the system and includes the OEM 1176144 24V terminal barrier for safe, organized low-voltage connections. When a transformer fails, the entire control circuit goes dead — the thermostat blanks out and the unit won't respond to any call — so a working transformer is essential to system operation.

Specifications

Spec Value
OEM Part Numbers 1173691 (transformer), 1176144 (24V barrier)
Type Step-Down Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208/230 VAC
Secondary Voltage 24 VAC
Fits Model WPA3364000RKC1

Compatibility

Direct-fit replacement for the ICP WPA3364000RKC1 heat pump and related Tempstar, Heil, and Comfortmaker units using a 40VA 208/230-to-24V control transformer. Verify the primary voltage tap and VA rating on your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power and pull the outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the control panel cover.
  3. Document — Photograph the primary and secondary wiring before disconnecting.
  4. Remove — Unbolt the old transformer and transfer the leads one at a time.
  5. Install — Mount the new transformer, land the 208/230V primary on the correct tap, and connect the 24V secondary per your photo.
  6. Test — Restore power and confirm 24V at the secondary and a responsive thermostat.

Signs You Need a Replacement

  • Thermostat is dead or screen is blank
  • No 24V output at the secondary terminals
  • Unit won't respond to any heating or cooling call
  • Burnt smell or visibly scorched transformer body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPA3364000RKC1 — 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPA3364000RKC1 — 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPA3364000RKC1 — 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online