Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WPA3244000RKC1 — 208/230V to 24V | Ships Today
ICP

ICP 40VA Transformer for WPA3244000RKC1 — 208/230V to 24V | Ships Today

SKU: 1176144-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer (OEM 1173691) steps 208/230V line power down to the 24V control voltage that runs the contactor coil, defrost board, and thermostat circuit in your ICP/Tempstar/Heil WPA3244000RKC1 heat pump. Rated at 40VA, it supplies the low-voltage power the entire control system depends on. The kit also includes the 24V terminal barrier (OEM 1176144) used to organize and protect the low-voltage connections. When a transformer fails — from a shorted thermostat wire, an overloaded coil, or simple age — the unit goes completely dead on the control side: no fan, no compressor, and an unresponsive thermostat. Replacing it restores 24V power and brings the system back to life.

Specifications

Spec Value
Part Numbers 1173691 (transformer), 1176144 (24V barrier)
Type Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V

Compatibility

Direct-fit OEM replacement for the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire WPA3244000RKC1 heat pump and other ICP-family units using a 40VA 208/230-to-24V control transformer. Confirm the VA rating and primary/secondary voltages stamped on your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-panel cover to expose the transformer.
  3. Document — Photograph the primary (line) and secondary (24V) leads and the barrier connections before disconnecting.
  4. Remove — Disconnect the leads, unbolt the transformer from the panel, and remove the old barrier if reusing the location.
  5. Install — Mount the new transformer and barrier, then reconnect each lead to the matching terminal per your photo.
  6. Test — Restore power and verify 24V across the secondary terminals and normal system operation.

Signs You Need a Replacement

  • No 24V control power; thermostat is dead
  • Compressor and fan won't energize
  • Burnt smell or discolored transformer housing
  • Zero or incorrect voltage on the secondary terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WPA3244000RKC1 — 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WPA3244000RKC1 — 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WPA3244000RKC1 — 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online