This OEM 40VA control transformer (part number 1173691) supplies the 24V low-voltage power that runs the entire control circuit of the ICP/Heil/Tempstar WJH342000KTP0A2 heat pump. It steps 208/230V line voltage down to 24V to energize the thermostat, contactor coil, reversing-valve coil, and safety controls. When a transformer fails, the system goes completely dead at the low-voltage side: no thermostat display, no contactor pull-in, and no response to a call for heating or cooling. Transformers fail from a shorted control wire, a shorted coil, or sustained overload. This unit is rated at 40VA to carry the full control load of the WJH342000KTP0A2 reversing-valve heat pump system.
| Spec | Value |
|---|---|
| OEM Part Number | 1173691 |
| Type | Step-Down Control Transformer |
| Brand | ICP / Heil / Tempstar |
| Rating | 40 VA |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| Related OEM Parts | 1176032 (24V Barrier), 1172619 (Rev Valve Coil 24V), 1173708 (Reversing Valve w/Coil 24V) |
Direct OEM replacement for the ICP/Heil/Tempstar WJH342000KTP0A2 heat pump control circuit. The 208/230V-to-24V, 40VA configuration is a common service transformer across many residential heat pump and air handler boards. Verify primary and secondary voltage and VA rating against the original before installing.