ICP 40VA Transformer for WJH336000K000A1 — 208/230V to 24V | Ships Today
ICP

ICP 40VA Transformer for WJH336000K000A1 — 208/230V to 24V | Ships Today

SKU: 1176032-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 40VA control transformer (part #1173691) for the ICP / Heil / Tempstar WJH336000K000A1 packaged heat pump. It steps the unit's 208/230V line voltage down to the 24V low-voltage control circuit that powers the thermostat, contactor coil, and reversing-valve solenoid. This listing also covers the related low-voltage control components shipped for this model: the 24V reversing-valve coil (#1172619), the reversing valve with coil (#1173708), and the 24V barrier (#1176032). When the transformer fails, the entire 24V control side goes dead — no contactor pull-in, no compressor, no fan. Common failure causes are a shorted secondary, a seized contactor coil that overloads the transformer, or age-related winding breakdown.

Specifications

Spec Value
Part Number 1173691 (transformer)
Type Control Transformer
Brand ICP / Heil / Tempstar
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V
Related Parts 1176032, 1172619, 1173708

Compatibility

Engineered for the ICP-family WJH336000K000A1 packaged heat pump and shared across Heil, Tempstar, and Comfortmaker units that use this control platform. Always confirm the printed primary/secondary voltage and VA rating against your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter at the unit.
  2. Access — Remove the control-panel service panel.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Disconnect the primary and secondary leads, then unbolt the failed transformer from the panel.
  5. Install — Mount the new transformer, match the primary taps to your supply voltage, and reconnect the 24V secondary per your photo.
  6. Test — Restore power and confirm 24V at the secondary and proper contactor pull-in.

Signs You Need a Replacement

  • No 24V at the thermostat or control board
  • Contactor will not pull in and compressor never starts
  • Visible scorching, bulging, or a burnt smell at the transformer
  • Repeatedly blown low-voltage fuse traced to the transformer secondary

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WJH336000K000A1 — 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WJH336000K000A1 — 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WJH336000K000A1 — 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.