OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is the OEM 40VA control transformer (part #1173691) for the ICP/Heil/Tempstar WJH324000KTP0A2 heat pump. It steps line voltage (208/230V) down to the 24V control voltage that powers the thermostat circuit, contactor coil, reversing-valve solenoid, and defrost board. When this transformer fails, the entire low-voltage control system loses power — the unit won't respond to the thermostat even with line voltage present. Typical symptoms include a dead/unresponsive system, a repeatedly blown 24V fuse, a buzzing or scorched transformer, or 0 volts across the secondary terminals. The 40VA rating supplies adequate headroom for the reversing-valve coil and contactor loads on this heat pump.
| Spec | Value |
|---|---|
| Part Number | 1173691 |
| Type | Control Transformer |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| Rating | 40 VA |
| Associated Parts | 1176032 Barrier 24V, 1172619 Rev-Valve Coil 24V, 1173715 Reversing Valve w/Coil 24V |
Fits the ICP/Heil/Tempstar/Comfortmaker WJH324000KTP0A2 heat pump and other units in this platform using a 208/230V-to-24V 40VA control transformer. Always confirm primary/secondary voltage and VA rating against the unit being serviced.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.