Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WJA336000K000A2 – 208/230V to 24V | Ships Today
ICP

ICP 40VA Transformer for WJA336000K000A2 – 208/230V to 24V | Ships Today

SKU: 1176032 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 40VA control transformer (part #1173691) with its terminal barrier (part #1176032) powers the 24-volt control circuit on ICP, Tempstar, and Heil model WJA336000K000A2 units. It steps the 208/230V line voltage down to the 24V needed by the thermostat, contactor coil, control board, and safety switches. When a transformer fails, the entire low-voltage control system goes dead — no thermostat call, no contactor pull-in, and no cooling or heating — even though line voltage is present. The included barrier protects and isolates the secondary terminals to prevent shorts.

Specifications

Spec Value
Part Number 1173691 (transformer), 1176032 (24V barrier)
Type Control / Step-Down Transformer
Brand ICP (Tempstar / Heil)
Rating 40 VA
Primary Voltage 208/230 VAC
Secondary Voltage 24 VAC
Fits Model WJA336000K000A2
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the WJA336000K000A2 and other ICP-family systems using a 40VA 208/230-to-24V transformer. Verify your existing primary tap voltage and VA rating before installing.

Installation Guide

  1. Safety First – Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access – Remove the control-panel service cover.
  3. Document – Photograph all primary and secondary wiring, noting the 208 vs 230 primary tap in use.
  4. Remove – Label and disconnect the transformer leads, then unbolt the old transformer and barrier.
  5. Install – Mount the new transformer and barrier, wire the correct primary tap, and reconnect the 24V secondary per your photo.
  6. Test – Restore power and confirm ~24 VAC at the secondary and a normal thermostat call.

Signs You Need a Replacement

  • No 24V at the thermostat or control board
  • Contactor will not pull in even with a cooling call
  • Burnt smell or visibly scorched transformer windings
  • Repeated blown low-voltage fuses

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WJA336000K000A2 – 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WJA336000K000A2 – 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WJA336000K000A2 – 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online