Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WFSR120D060A1 — 120V to 24V | Ships Today
ICP

ICP 40VA Transformer for WFSR120D060A1 — 120V to 24V | Ships Today

SKU: 1177217-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control transformer (part 1177217) for the ICP/Tempstar/Heil WFSR120D060A1 gas furnace. Rated 40VA with a 120V primary and 24V secondary, it steps line voltage down to the 24 VAC control voltage that powers the thermostat, gas valve, and control board. A failed transformer means no control power — the furnace simply won't respond to a heat call. This is a common, low-cost failure point worth keeping on the truck.

Specifications

Spec Value
Part Number 1177217
Type Step-down control transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 120 VAC
Secondary Voltage 24 VAC

Compatibility

Direct OEM replacement for the WFSR120D060A1 furnace and other ICP-family equipment using a 40VA 120/24V control transformer. Confirm your primary voltage tap is 120V and that the VA rating matches before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the transformer mounted in the control area.
  3. Document — Photograph the primary (line) and secondary (24V) lead connections before disconnecting.
  4. Remove — Disconnect the leads, unbolt the transformer from its mounting bracket, and remove it.
  5. Install — Mount the new transformer, reconnect the 120V primary and 24V secondary leads per your photo, and secure all connections.
  6. Test — Restore power and verify 24 VAC across the secondary terminals and a normal heat call response.

Signs You Need a Replacement

  • No 24V control power — furnace dead to a thermostat call
  • Repeatedly blown low-voltage fuse on the control board
  • Burnt smell or discolored transformer housing
  • Measured secondary voltage absent or well below 24 VAC

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFSR120D060A1 — 120V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFSR120D060A1 — 120V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFSR120D060A1 — 120V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online