Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WFML135D066B1 — 120/24V OEM 1177217 | Ships Today
ICP

ICP 40VA Transformer for WFML135D066B1 — 120/24V OEM 1177217 | Ships Today

SKU: 1177217-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control transformer (part number 1177217) is the factory step-down transformer for the ICP / Heil / Tempstar WFML135D066B1 gas furnace. Rated 40VA with a 120V primary and 24V secondary, it converts incoming line voltage into the low-voltage 24V control power that runs the thermostat, gas valve, control board, and safety circuits. When a transformer fails — usually from a short, an overload, or age — the entire low-voltage control system goes dead: the thermostat screen blanks, the furnace won't respond to a call for heat, and no relays or valves energize. A fresh transformer restores reliable 24V power to the whole control circuit.

Specifications

Spec Value
Part Number 1177217
Type Step-down control transformer
Brand ICP / Heil / Tempstar
Rating 40 VA
Primary Voltage 120 V
Secondary Voltage 24 V
Fit OEM exact replacement

Compatibility

Direct factory replacement for the ICP / Heil / Tempstar / Comfortmaker WFML135D066B1 furnace and other ICP-family units using a 40VA 120V-to-24V control transformer. Confirm primary/secondary voltages and VA rating against your existing unit.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter at both primary and secondary leads.
  2. Access — Remove the control/electrical compartment service panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Disconnect the primary (line) and secondary (24V) leads, then unbolt the transformer from its bracket.
  5. Install — Mount the new transformer, reconnect primary and secondary leads per your photo, and confirm a solid ground.
  6. Test — Restore power and measure 24V across the secondary; confirm the thermostat powers up and the furnace responds to a heat call.

Signs You Need a Replacement

  • Blank thermostat / no low-voltage power
  • Furnace won't respond to a call for heat
  • Burnt smell or visible scorching on the transformer
  • 0V reading across the 24V secondary with line voltage present

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFML135D066B1 — 120/24V OEM 1177217 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFML135D066B1 — 120/24V OEM 1177217 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFML135D066B1 — 120/24V OEM 1177217 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online