OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This genuine OEM control transformer (ICP part number 1176944) steps the 120V line voltage down to the 24V control power that runs your furnace circuit board, thermostat, gas valve, and igniter circuit on the ICP / Heil / Tempstar WFML090B042A1. A failed transformer is one of the most common causes of a completely dead furnace: no thermostat display, no blower, no ignition sequence. Rated at 40VA, it supplies enough current for the full control load while protecting downstream components. If you have measured 120V at the primary but no 24V at the secondary, the transformer has failed and should be replaced.
| Spec | Value |
|---|---|
| Part Number | 1176944 |
| Type | Control / Step-Down Transformer |
| Brand | ICP / Heil / Tempstar |
| Rating | 40 VA |
| Primary Voltage | 120V |
| Secondary Voltage | 24V |
| Fitment | OEM exact-fit |
Built for the ICP / Heil / Tempstar WFML090B042A1 gas furnace and other ICP-family furnaces using a 120/24V 40VA control transformer. Confirm primary voltage and VA rating against your existing unit before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.