Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WFML070A036A1 — 120/240V to 24V | Ships Today
ICP

ICP 40VA Transformer for WFML070A036A1 — 120/240V to 24V | Ships Today

SKU: 1176944-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control transformer (part number 1176944) supplies the 24-volt low-voltage power that runs the WFML070A036A1 furnace's control board, gas valve, thermostat circuit, and safety controls. It steps the 120/240V line voltage down to a 24V secondary at 40VA. When a transformer fails — usually from a shorted thermostat wire, a stuck contactor, or simple age — the furnace goes completely dead: no thermostat display, no blower, no ignition sequence. Because the entire control system depends on it, the transformer is one of the most critical low-cost components in the unit.

Specifications

Spec Value
Part Number 1176944
Type Step-Down Control Transformer
Brand ICP (Heil / Tempstar / Comfortmaker)
Rating 40 VA
Primary Voltage 120 / 240 VAC
Secondary Voltage 24 VAC
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar WFML070A036A1 gas furnace and other ICP-family units calling for a 40VA, 120/240V-to-24V control transformer. Verify your primary voltage tap before wiring.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every primary and secondary lead before disconnecting.
  4. Remove — Unfasten the mounting screws and disconnect the transformer leads.
  5. Install — Mount the new transformer, match the correct primary tap (120V vs 240V), and reconnect the 24V secondary per your photo.
  6. Test — Restore power, confirm 24VAC at the secondary, and verify the thermostat and control board power up.

Signs You Need a Replacement

  • Furnace is completely unresponsive — no thermostat display
  • No 24V reading at the control board or gas valve
  • Blown low-voltage fuse that keeps failing
  • Burnt smell or visible scorching on the transformer body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFML070A036A1 — 120/240V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFML070A036A1 — 120/240V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFML070A036A1 — 120/240V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online