This OEM 40VA control transformer is the original low-voltage power supply for the ICP/Heil/Tempstar WFHR040B036A1 gas furnace, part number 1177217. It steps line-voltage 120V down to the 24V the control board, thermostat, and gas valve require. A burned-out or shorted transformer leaves the entire 24V control circuit dead — no thermostat response, no ignition, and often a blown fuse on the board. The 40VA rating provides the current headroom these furnace controls demand.

Specifications

Spec Value
Part Number 1177217
Rating 40 VA
Primary Voltage 120V
Secondary Voltage 24V
Type Control Transformer
Brand ICP / Heil / Tempstar / Comfortmaker
Fitment OEM Direct Replacement

Compatibility

Built for the WFHR040B036A1 furnace and used across ICP-family WFHR-series furnaces under the Heil, Tempstar, Comfortmaker, and Arcoaire labels. Confirm the 40VA rating and 120/24V configuration match your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph the primary and secondary wiring before disconnecting.
  4. Remove — Disconnect the leads, unbolt the transformer from its bracket, and remove it.
  5. Install — Mount the new transformer and reconnect the 120V primary and 24V secondary leads exactly per your photo.
  6. Test — Restore power and verify 24V across the secondary terminals, then confirm normal furnace operation.

Signs You Need a Replacement

  • No 24V control power; thermostat and furnace dead
  • Repeated blown control-board fuses
  • Burning smell or scorched transformer housing
  • Buzzing transformer with no secondary output

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFHR040B036A1 — 120/24V OEM 1177217 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFHR040B036A1 — 120/24V OEM 1177217 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFHR040B036A1 — 120/24V OEM 1177217 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online