This OEM 40VA control transformer (part 1177217) steps 120V line power down to the 24V control voltage that powers the ICP Tempstar/Heil WFEL070B036A1 furnace's thermostat, gas valve, relays, and control board logic. Rated at 40VA with a 120V primary and 24V secondary, it is the foundation of the low-voltage control circuit. When the transformer fails — usually from a shorted secondary, an overloaded accessory, or simple age — the entire 24V system goes dead: no thermostat call, no ignition, no cooling. A blown transformer is a frequent root cause behind a furnace that appears completely unresponsive.

Specifications

Spec Value
Part Number 1177217
Type Step-Down Control Transformer
Rating 40 VA
Primary Voltage 120V
Secondary Voltage 24V
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement

Compatibility

Built for the ICP Tempstar/Heil WFEL070B036A1 furnace and shared ICP-family controls using the 40VA 120/24V transformer. Confirm primary voltage and VA rating against your existing unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph the primary (line) and secondary (24V) lead connections before disconnecting.
  4. Remove — Disconnect the leads, remove the transformer mounting screw or bracket, and lift out the failed unit.
  5. Install — Mount the new 1177217 transformer, reconnect the 120V primary and 24V secondary leads exactly per your photos, and secure all connections.
  6. Test — Restore power and confirm ~24V at the secondary and a normal thermostat call/ignition sequence.

Signs You Need a Replacement

  • Furnace completely unresponsive — no 24V control power.
  • No voltage at the thermostat or gas valve terminals.
  • Transformer is hot, buzzing, or smells burnt.
  • Repeatedly blown low-voltage fuse on the control board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFEL070B036A1 — 120/24V OEM Furnace Transformer | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFEL070B036A1 — 120/24V OEM Furnace Transformer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFEL070B036A1 — 120/24V OEM Furnace Transformer | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online