Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WFAR080B048B2 — 120V to 24V Control | Ships Today
ICP

ICP 40VA Transformer for WFAR080B048B2 — 120V to 24V Control | Ships Today

SKU: 1177217 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40VA control transformer (part number 1177217) supplies the low-voltage power for your ICP/Heil/Tempstar WFAR080B048B2 gas furnace. It steps the 120V line voltage down to the 24V used by the thermostat, control board, gas valve, and relays. When the transformer fails, the entire low-voltage control circuit goes dead — the furnace won't respond to the thermostat, the control board shows no power, and nothing energizes even though 120V is present. A transformer can fail from age, a shorted secondary circuit, or a blown internal fuse link, often producing a faint burnt-electrical smell.

Specifications

Spec Value
Part Number 1177217
Type Control Transformer
Brand ICP / Heil / Tempstar
Rating 40 VA
Primary Voltage 120V
Secondary Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Designed for the ICP/Heil/Tempstar/Comfortmaker WFAR080B048B2 80,000 BTU gas furnace. This OEM 40VA transformer matches the factory primary/secondary voltages and mounting so it drops directly into the original location.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter before touching wiring.
  2. Access — Remove the service panel to reach the control box and transformer.
  3. Document — Photograph the primary (line) and secondary (24V) wiring before disconnecting.
  4. Remove — Disconnect the primary and secondary leads, remove the mounting screws, and take out the failed transformer.
  5. Install — Mount the new transformer, reconnect the 120V primary and 24V secondary leads per your photo, and confirm tight terminals.
  6. Test — Restore power and verify 24V across the secondary, then confirm the furnace responds to a thermostat call.

Signs You Need a Replacement

  • No 24V control power and the furnace ignores the thermostat.
  • Control board is completely dead despite 120V at the furnace.
  • Burnt-electrical smell or discoloration at the transformer.
  • 0V measured across the secondary terminals with line power present.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFAR080B048B2 — 120V to 24V Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFAR080B048B2 — 120V to 24V Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFAR080B048B2 — 120V to 24V Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online