Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WFAR060B048B2 — 120V to 24V Furnace Control | Ships Today
ICP

ICP 40VA Transformer for WFAR060B048B2 — 120V to 24V Furnace Control | Ships Today

SKU: 1177217-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 40VA control transformer (part number 1177217) steps the 120-volt line supply down to the 24-volt control voltage used by your ICP/Tempstar/Heil WFAR060B048B2 furnace. It powers the control board, thermostat circuit, gas valve, and low-voltage relays. When a transformer fails — usually from a shorted thermostat wire, a stuck contactor, or simple age — the furnace goes completely dead with no display, no blower, and no call-for-heat response. Replacing it with the correct 40VA unit restores reliable low-voltage power to the entire control system.

Specifications

Spec Value
Part Number 1177217
Type Step-Down Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 120 VAC
Secondary Voltage 24 VAC
Fit OEM direct replacement

Compatibility

Engineered for the ICP/Tempstar/Heil WFAR060B048B2 gas furnace and other ICP-family models specifying a 40VA, 120V-to-24V control transformer. Verify your primary supply is 120V before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower service panel.
  3. Document — Photograph all primary (line) and secondary (24V) wire connections before disconnecting.
  4. Remove — Disconnect the leads, remove the transformer mounting screws, and lift it out.
  5. Install — Mount the new transformer, reconnect the 120V primary and 24V secondary leads exactly per your photo.
  6. Test — Restore power, confirm 24VAC at the secondary, and verify the furnace responds to a call for heat.

Signs You Need a Replacement

  • Furnace completely dead — no control board display or thermostat power
  • No 24VAC measured at the secondary terminals
  • Blown low-voltage fuse that recurs after reset
  • Burnt smell or visibly scorched transformer housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WFAR060B048B2 — 120V to 24V Furnace Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WFAR060B048B2 — 120V to 24V Furnace Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WFAR060B048B2 — 120V to 24V Furnace Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.