Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for WAXT484A2 — 208/230V to 24V | Ships Today
ICP

ICP 40VA Transformer for WAXT484A2 — 208/230V to 24V | Ships Today

SKU: 1172028-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control transformer (part number 1172028) is the replacement for the ICP / Tempstar / Heil WAXT484A2. The transformer steps the incoming 208/230-volt line voltage down to the 24-volt control voltage that powers your thermostat, contactor coil, relays, and control board. It is rated at 40VA, providing enough capacity to drive the standard low-voltage control circuit. When a transformer fails — usually from a shorted thermostat wire, a stuck contactor drawing excessive current, or simple age — the entire 24V control system goes dead: the thermostat screen blanks, the contactor will not pull in, and the system will not respond to any call for heating or cooling.

Specifications

Spec Value
Part Number 1172028
Type Step-Down Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208/230 VAC
Secondary Voltage 24 VAC
Fits Model WAXT484A2

Compatibility

Direct OEM replacement for the ICP, Tempstar, Heil, and Comfortmaker WAXT484A2. A 40VA 208/230-to-24V transformer of this configuration is widely used across residential condensing units and air handlers, but confirm your existing transformer's VA rating and primary/secondary voltages before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect. Verify zero voltage at the transformer primary leads with a multimeter.
  2. Access — Remove the service or control panel to reach the transformer and its wiring.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Disconnect the line-voltage primary leads and the 24V secondary leads, then unbolt the old transformer.
  5. Install — Mount the new transformer, matching the 208/230V primary taps to the line voltage and reconnecting the 24V secondary per your photo.
  6. Test — Restore power and measure 24 VAC across the secondary terminals, then confirm the thermostat and contactor respond.

Signs You Need a Replacement

  • Blank thermostat and no 24V control power
  • Contactor and relays will not energize
  • No 24 VAC reading across the secondary terminals
  • Burnt smell, discoloration, or a tripped/blown low-voltage fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WAXT484A2 — 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WAXT484A2 — 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WAXT484A2 — 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.