OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is a genuine OEM 40VA control transformer, part number 1172028, for the ICP/Tempstar/Heil WAXM604A2. It steps the 208/230V line voltage down to the 24V control circuit that powers the thermostat, relays, contactor coil, and control board. A failed transformer is one of the most common causes of a completely dead control system — no 24V means no call for heat or cool, a blank thermostat, and unresponsive relays. Transformers fail from shorted control wiring, a seized contactor coil, or age-related winding breakdown, often blowing the secondary fuse along with them. Replacing it restores 24V control power and brings the system back online.
| Spec | Value |
|---|---|
| Part Number | 1172028 |
| Type | Control / Step-Down Transformer |
| Brand | ICP |
| Rating | 40 VA |
| Primary Voltage | 208/230V |
| Secondary Voltage | 24V |
| Fitment | OEM Direct Replacement |
Direct OEM replacement for the ICP, Tempstar, Heil, Comfortmaker and related brand WAXM604A2. Verify the part number 1172028 and the 208/230V-to-24V, 40VA rating on your existing transformer before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.