ICP 40VA Transformer for WAXL244A2 — 208/230V to 24V | Ships Today
ICP

ICP 40VA Transformer for WAXL244A2 — 208/230V to 24V | Ships Today

SKU: 1172028-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 40VA control transformer (part number 1172028) for the ICP WAXL244A2 unit. The transformer steps the incoming 208/230-volt line down to the 24-volt control voltage that powers your thermostat, contactor coil, gas valve, and control board. With 40 VA of capacity it supplies enough current to energize multiple low-voltage components at once. When a transformer fails, the entire low-voltage control circuit goes dead — the thermostat screen goes blank, the contactor will not pull in, and the system simply will not start a heating or cooling call. A buzzing, overheated, or visibly scorched transformer is a clear sign the windings have shorted and the part needs replacement.

Specifications

Spec Value
Part Number 1172028
Type Step-Down Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Primary Voltage 208 / 230 V
Secondary Voltage 24 V
Fits Model WAXL244A2

Compatibility

This transformer is the factory replacement for the ICP WAXL244A2 and is shared across many Tempstar, Heil, and Comfortmaker branded units built on the same platform. Always confirm the printed part number 1172028 and the 208/230V-to-24V, 40VA rating against the component currently installed in your equipment before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the transformer terminals with a multimeter.
  2. Access — Remove the unit service panel to expose the control box.
  3. Document — Photograph all primary and secondary wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line-voltage primary leads and the 24V secondary leads, then unbolt the failed transformer from its mounting bracket.
  5. Install — Mount the new transformer, reconnect the primary leads to the matching line voltage (208/230V) tap and the secondary leads to the 24V circuit per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals and normal system startup.

Signs You Need a Replacement

  • Thermostat is blank or unresponsive with no 24V present
  • Contactor or gas valve will not energize on a call
  • Transformer is hot, buzzing loudly, or smells burnt
  • Repeated blown low-voltage fuses tracing back to the transformer

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WAXL244A2 — 208/230V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WAXL244A2 — 208/230V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WAXL244A2 — 208/230V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.