Overview

This genuine ICP control transformer (OEM part 1172028) steps the 208/230V line voltage down to the 24V control voltage that powers the thermostat, relays, and low-voltage circuits in the WAHL184B2. Rated at 40VA, it supplies the control current the system needs to call for heat and cooling. A failed transformer leaves the system completely dead at the thermostat — no display, no relay clicks, and no response to a call. Open windings or a shorted secondary are common failure modes, often triggered by a low-voltage short downstream.

Specifications

Spec Value
Part Number 1172028
Type Control Transformer
Brand ICP (Tempstar / Heil)
Rating 40 VA
Primary Voltage 208/230V
Secondary Voltage 24V
Fitment OEM Replacement

Compatibility

The factory-correct 40VA control transformer for the ICP WAHL184B2 and matching Tempstar, Heil, and Comfortmaker chassis. Verify the primary tap and VA rating against your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Unhook the wiring and unbolt the old transformer from the mounting bracket.
  5. Install — Mount the new transformer, land the primary on the correct 208 or 230V tap, and reconnect the 24V secondary per your photo.
  6. Test — Restore power, confirm 24V at the secondary, and verify the thermostat powers up.

Signs You Need a Replacement

  • Thermostat is blank and the system is fully unresponsive
  • No 24V reading across the secondary terminals
  • Repeated blown control fuse
  • Burnt smell or visibly scorched transformer body

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WAHL184B2 — 208/230V to 24V OEM 1172028 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WAHL184B2 — 208/230V to 24V OEM 1172028 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WAHL184B2 — 208/230V to 24V OEM 1172028 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.