This OEM transformer (part #1011626) is the 115V-to-24V control transformer for ICP, Tempstar, and Heil gas furnaces. It steps down 115V line voltage to the 24V low-voltage control circuit that powers your thermostat, gas valve, igniter relay, and control board. Rated at 40VA, it supplies the steady control current the furnace needs to cycle safely. When a transformer fails — usually from a shorted secondary, an overloaded control circuit, or age-related winding breakdown — the furnace goes completely dead: no thermostat display, no blower, no ignition. A blown transformer is one of the most common no-heat call causes and often takes out a board fuse with it.
| Spec | Value |
|---|---|
| Part Number | 1011626 |
| Type | Step-Down Control Transformer |
| Brand | ICP / Tempstar / Heil |
| Primary Voltage | 115V |
| Secondary Voltage | 24V |
| Rating | 40VA |
| Fit | OEM Direct Replacement |
Direct-fit replacement for ICP Tempstar Heil model VNK100J16A1 and shares the same 1011626 transformer used across many ICP-family gas furnaces and air handlers built on the same control platform. Always confirm the part number on your existing transformer before ordering.