Overview

This OEM control transformer (part number 1011626, TRANS 115>24 40VA S) steps down 115-volt line power to the 24-volt control voltage your ICP Tempstar Heil VNK075F14B1 furnace needs to operate the thermostat, gas valve, control board, and relays. Rated at 40VA, it supplies enough current to drive the full low-voltage control circuit. When a transformer fails — usually from a shorted control wire, a stuck contactor, or simple age — the entire 24V system goes dead: the thermostat screen blanks, the furnace will not respond to a call for heat, and nothing energizes even though line power is present. A buzzing, scorched, or hot-to-the-touch transformer is a classic sign of impending failure or an upstream short that should be corrected before installing the replacement.

Specifications

Spec Value
Part Number 1011626
Description TRANS 115>24 40VA S
Type Step-Down Control Transformer
Primary Voltage 115V
Secondary Voltage 24V
Rating 40VA
Brand ICP / Tempstar / Heil
Fits Model VNK075F14B1
Fit OEM Replacement

Compatibility

Direct OEM replacement for the ICP Tempstar Heil VNK075F14B1 furnace. The 115V-to-24V 40VA transformer is a common control component shared across many ICP-family gas furnaces (Tempstar, Heil, Comfortmaker). Confirm your primary voltage and VA rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph all primary (line) and secondary (24V) wire connections before disconnecting.
  4. Remove — Disconnect the leads, remove the transformer mounting screw(s), and take out the old transformer.
  5. Install — Mount the new transformer, then reconnect the primary and secondary leads exactly per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals and normal furnace operation on a call for heat.

Signs You Need a Replacement

  • Thermostat is blank and the furnace is completely unresponsive.
  • No 24V measured at the secondary terminals with line power present.
  • Transformer is buzzing, hot, or has a burnt smell.
  • Repeated blown fuses on the control board after a short.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP VNK075F14B1 — 115V to 24V Control Transformer | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP VNK075F14B1 — 115V to 24V Control Transformer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP VNK075F14B1 — 115V to 24V Control Transformer | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.