Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for VNE125J20G1 — 115V to 24V | Ships Today
ICP

ICP 40VA Transformer for VNE125J20G1 — 115V to 24V | Ships Today

SKU: 1012722-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control transformer (part 1012722, TRANS 115>24 40VA X) supplies the low-voltage power your ICP Tempstar Heil VNE125J20G1 furnace needs to operate. It steps 115V line voltage down to 24V at 40VA, powering the control board, gas valve, thermostat circuit, and contactor coil. A failed transformer leaves the furnace completely dead on a heat call — no display, no blower, no ignition — even though line power is present. Transformers commonly fail from a shorted thermostat wire, a stuck gas-valve coil, or simple age-related winding breakdown.

Specifications

Spec Value
Part Number 1012722
Description TRANS 115>24 40VA X
Type Control Transformer
Brand ICP / Tempstar / Heil
Primary Voltage 115V
Secondary Voltage 24V
Rating 40VA
Fits Model VNE125J20G1

Compatibility

Designed for the ICP Tempstar Heil VNE125J20G1 furnace and interchangeable across many ICP-family (Comfortmaker, Arcoaire, KeepRite) units using a 115V-to-24V 40VA control transformer. Verify the primary tap and VA rating against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel to reach the transformer.
  3. Document — Photograph every primary and secondary lead before disconnecting.
  4. Remove — Disconnect the wires, remove the mounting screws, and lift out the old transformer.
  5. Install — Mount the new transformer, then reconnect 115V primary and 24V secondary leads exactly per your photo.
  6. Test — Restore power and confirm 24V at the secondary and normal furnace operation on a heat call.

Signs You Need a Replacement

  • Furnace is completely unresponsive despite confirmed 115V line power
  • No 24V reading at the control board or thermostat terminals
  • Blown low-voltage fuse that re-blows after replacement
  • Burnt smell or discolored windings at the transformer

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP VNE125J20G1 — 115V to 24V | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP VNE125J20G1 — 115V to 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP VNE125J20G1 — 115V to 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online