Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for RHX036K0XA0AAA — 24V Control Output | Ships Today
ICP

ICP 40VA Transformer for RHX036K0XA0AAA — 24V Control Output | Ships Today

SKU: 1172619-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 40VA control transformer (part numbers 1172619 and 1175367) supplies the 24-volt low-voltage power that runs the control circuit of the ICP RHX036K0XA0AAA heat pump. It steps line voltage down to 24V to energize the contactor coil, reversing-valve solenoid, defrost board, and thermostat circuit. Rated at 40VA, it provides enough capacity to pull in multiple loads simultaneously without sagging. When a transformer fails — usually from a shorted thermostat wire, a stuck contactor coil, or a power surge — the entire control circuit goes dead: the thermostat screen may go blank, the contactor will not pull in, and the system simply will not respond to a call. A burnt-out transformer often has a scorched smell or a popped internal fuse link.

Specifications

Spec Value
OEM Part Numbers 1172619, 1175367
Type Control Transformer
Brand ICP / Tempstar / Heil / Comfortmaker
Rating 40 VA
Secondary Voltage 24V
Application Heat Pump Control Circuit

Compatibility

A direct OEM replacement for the ICP RHX036K0XA0AAA heat pump and the related Tempstar, Heil, and Comfortmaker units that use this 40VA 24V control transformer. Confirm the part number and secondary voltage stamped on your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control panel cover to reach the transformer.
  3. Document — Photograph the primary (line) and secondary (24V) wiring before disconnecting.
  4. Remove — Disconnect all leads and unbolt the failed transformer from its bracket.
  5. Install — Mount the new transformer and reconnect the primary and secondary wires per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals and normal system operation.

Signs You Need a Replacement

  • Thermostat is blank and the system is completely unresponsive.
  • No 24V measured across the secondary terminals.
  • Burnt smell or discoloration on the transformer body.
  • Repeated control-fuse blowing after a wiring short is corrected.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHX036K0XA0AAA — 24V Control Output | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHX036K0XA0AAA — 24V Control Output | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHX036K0XA0AAA — 24V Control Output | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online