Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for RHS048H0BA0AAAA — 24V Control | Ships Today
ICP

ICP 40VA Transformer for RHS048H0BA0AAAA — 24V Control | Ships Today

SKU: 1175367 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control component (part 1175367) supplies the 24-volt control circuit for the ICP / Tempstar / Heil RHS048H0BA0AAAA. A control transformer steps line voltage down to the 24VAC needed by the thermostat, contactor coil, reversing-valve solenoid, and control board. Rated at 40VA, it provides enough capacity to hold all low-voltage loads pulled in at once. When a transformer fails — usually from a shorted secondary or a surge — the entire control circuit goes dead: the thermostat blanks, the contactor won't pull in, and the system won't respond to a call. Note: the OEM description for 1175367 reads "VALVE REV W/ COIL 24V," which indicates a reversing-valve coil; confirm the correct part before ordering against this transformer listing.

Specifications

Spec Value
Part Number 1175367
Type Control Transformer
Brand ICP / Tempstar / Heil
Rating 40 VA
Secondary Voltage 24 VAC
Fit OEM Replacement

Compatibility

Intended for the ICP RHS048H0BA0AAAA 4-ton heat pump and equivalent Tempstar, Heil, and Comfortmaker units using the 1175367 number. Verify primary voltage and 24V secondary rating against your existing transformer before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter on both primary and secondary leads.
  2. Access — Remove the control-box service panel to expose the transformer.
  3. Document — Photograph the primary and 24V secondary wiring before disconnecting.
  4. Remove — Disconnect the leads, unbolt the transformer from the control box, and lift it out.
  5. Install — Mount the new transformer and reconnect each lead to the matching terminal per your photo.
  6. Test — Restore power and confirm a steady 24VAC across the secondary and that the system responds to a thermostat call.

Signs You Need a Replacement

  • No 24V at the control board or thermostat.
  • Thermostat screen is blank with line power present.
  • Repeated blown low-voltage fuses or a burnt-smelling transformer.
  • Contactor and controls won't energize on a call.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHS048H0BA0AAAA — 24V Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHS048H0BA0AAAA — 24V Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHS048H0BA0AAAA — 24V Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online