Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40VA Transformer for RHH102S0AA0AAAA — 24V Control Output | Ships Today
ICP

ICP 40VA Transformer for RHH102S0AA0AAAA — 24V Control Output | Ships Today

SKU: 1172619-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 24V control transformer supplies low-voltage power to the 24V control circuit of your ICP (International Comfort Products) RHH102S0AA0AAAA heat pump. Rated at 40VA, it steps line voltage down to the 24V secondary that energizes contactors, reversing valve coils, control boards, and the thermostat circuit. When a transformer fails, the entire low-voltage control side goes dead — no thermostat response, no contactor pull-in, and no compressor or fan operation. Replacing it with the correct OEM-rated 40VA unit restores reliable 24V control power. Related OEM control components on this unit include reversing valve coil 1172619 and reversing valve assembly 1175367.

Specifications

Spec Value
Reference Part Numbers 1172619, 1175367
Type Control Transformer
Brand ICP
Rating 40 VA
Secondary Voltage 24V
Application Heat Pump Control Circuit

Compatibility

Engineered for the ICP / Tempstar / Heil RHH102S0AA0AAAA heat pump and equivalent models sharing the same 24V/40VA control platform. Always confirm against your unit's wiring diagram and rating plate before installation.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control-panel access cover.
  3. Document — Photograph all primary and secondary wire connections before disconnecting.
  4. Remove — Disconnect the primary and 24V secondary leads, unbolt the transformer from its bracket.
  5. Install — Mount the new transformer and reconnect primary/secondary leads exactly per your photo.
  6. Test — Restore power and confirm 24V across the secondary terminals.

Signs You Need a Replacement

  • No 24V reading at the secondary terminals
  • Thermostat goes blank or unresponsive
  • Contactor will not pull in on a call for cooling/heating
  • Visible burn marks, swelling, or a burnt-electrical smell

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP RHH102S0AA0AAAA — 24V Control Output | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP RHH102S0AA0AAAA — 24V Control Output | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP RHH102S0AA0AAAA — 24V Control Output | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online