This genuine OEM 40A contactor (part number 1176763) is the high-voltage switch that powers the compressor and condenser fan motor on the ICP / Tempstar / Heil WCH4604GKB100 heat pump. When the thermostat calls for cooling or heating, the unit's 24V control circuit energizes the contactor coil, pulling the contacts closed and sending line voltage to the compressor. Contactors are a leading cause of no-cool and no-heat calls because their contacts pit, burn, and weld over thousands of cycles. Symptoms of a failing contactor include a humming or chattering sound, contacts that stick closed (unit runs constantly), or contacts that never close (unit is completely dead at the compressor).

Specifications

Spec Value
Part Number 1176763
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Rating 40 Amp
Coil Voltage 24V
Fit OEM

Compatibility

Designed for the ICP / Tempstar / Heil WCH4604GKB100 heat pump and compatible across the broader Tempstar, Heil, and Comfortmaker condensing unit line that uses a 40A, 24V-coil contactor. Verify amp rating, pole count, and coil voltage against the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph every wire on the line, load, and coil terminals before disconnecting.
  4. Remove — Unscrew the mounting screws and lift out the old contactor.
  5. Install — Mount the new contactor and transfer wires one at a time to the matching terminals per your photo.
  6. Test — Restore power and confirm the contacts pull in on a call for cooling.

Signs You Need a Replacement

  • Loud humming, buzzing, or chattering at the contactor
  • Compressor and fan won't start even with a 24V call
  • Contacts visibly pitted, burned, or welded together
  • Unit runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH4604GKB100 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH4604GKB100 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH4604GKB100 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.