This genuine OEM 40-amp definite purpose contactor (OEM #1176763) is the switching relay for the ICP/Heil/Tempstar WCH3602GKR2 heat pump. The contactor uses a low-voltage 24V control signal from the thermostat to close its line-voltage contacts, energizing the compressor and condenser fan motor. Over time the contacts pit, burn, and weld from constant arcing. A failed contactor is one of the most common causes of a condenser that won't start, that hums without running, or that won't shut off because the contacts have fused closed. Replacing it is a fast, low-cost repair that restores reliable compressor and fan operation.

Specifications

Spec Value
Part Number 1176763
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Contact Rating 40A
Coil Voltage 24V AC
Fits Model WCH3602GKR2 Heat Pump
Fit OEM

Compatibility

Built for the WCH3602GKR2 heat pump condensing unit and its ICP-family equivalents under the Heil, Tempstar, and Comfortmaker brands. Verify your existing contactor amp rating (40A) and 24V coil voltage before ordering.

Installation Guide

  1. Safety First — Shut off power at the disconnect and breaker, then confirm zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Disconnect all wiring, unscrew the contactor from its bracket, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and call for cooling; confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Condenser hums but compressor and fan won't start
  • Pitted, burned, or melted contacts visible on the contactor
  • System won't shut off because contacts are welded closed
  • Chattering or buzzing when the thermostat calls for cooling

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3602GKR2 Heat Pump — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3602GKR2 Heat Pump — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3602GKR2 Heat Pump — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online