OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This genuine OEM 40-amp definite purpose contactor (OEM #1176763) is the switching relay for the ICP/Heil/Tempstar WCH3602GKR2 heat pump. The contactor uses a low-voltage 24V control signal from the thermostat to close its line-voltage contacts, energizing the compressor and condenser fan motor. Over time the contacts pit, burn, and weld from constant arcing. A failed contactor is one of the most common causes of a condenser that won't start, that hums without running, or that won't shut off because the contacts have fused closed. Replacing it is a fast, low-cost repair that restores reliable compressor and fan operation.
| Spec | Value |
|---|---|
| Part Number | 1176763 |
| Type | Definite Purpose Contactor |
| Brand | ICP / Heil / Tempstar / Comfortmaker |
| Contact Rating | 40A |
| Coil Voltage | 24V AC |
| Fits Model | WCH3602GKR2 Heat Pump |
| Fit | OEM |
Built for the WCH3602GKR2 heat pump condensing unit and its ICP-family equivalents under the Heil, Tempstar, and Comfortmaker brands. Verify your existing contactor amp rating (40A) and 24V coil voltage before ordering.
Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.