Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40A Contactor for RHS060K0XB0AAAA — 24V Coil | Ships Today
ICP

ICP 40A Contactor for RHS060K0XB0AAAA — 24V Coil | Ships Today

SKU: 1176763-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 40-amp definite purpose contactor (part number 1176763) for the ICP/Tempstar/Heil RHS060K0XB0AAAA heat pump. The contactor is the high-voltage switch that sends line power to the compressor and condenser fan motor each time the 24V control coil is energized by a thermostat call. Over thousands of cycles the contacts pit, burn, or weld, which leads to an outdoor unit that hums without starting, a compressor that won't engage, or a unit that won't turn off. This 40A-rated contactor is a low-cost replacement that restores reliable starting and protects the more expensive compressor.

Specifications

Spec Value
Part Number 1176763
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 40 Amp
Coil Voltage 24V
Application Condenser / Heat Pump

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RHS060K0XB0AAAA and matching outdoor units that use a 40A, 24V-coil contactor. Confirm the amp rating and coil voltage printed on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit's electrical service panel.
  3. Document — Photograph every wire position on the contactor before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and verify the contactor pulls in and the compressor and fan start on a call.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Burned, pitted, or welded contacts on the old part
  • Loud buzzing or chattering from the contactor
  • Unit won't shut off because the contacts have welded closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS060K0XB0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS060K0XB0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS060K0XB0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online