Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 40A Contactor for RGX048KRCA0AAA — OEM Part 1176763 | Ships Today
ICP

ICP 40A Contactor for RGX048KRCA0AAA — OEM Part 1176763 | Ships Today

SKU: 1176763 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 40 amp contactor (part number 1176763) for the ICP / Heil / Tempstar RGX048KRCA0AAA system. A contactor is the high-current relay that switches line voltage to the motor and compressor loads when the 24V control coil is energized by the thermostat or control board. Rated at 40 amps with a 24V coil, this contactor handles the inrush and run current of the connected load. Contactors are a common wear item — the contacts pit and burn over thousands of cycles — so a fresh OEM contactor restores clean, reliable switching and eliminates chatter, weak pull-in, and welded-contact failures.

Specifications

Spec Value
OEM Part Number 1176763 (CONTACTOR 40A)
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Current Rating 40 Amps
Poles 2-Pole
Coil Voltage 24V
Fits Model RGX048KRCA0AAA
Fitment OEM Exact Replacement

Compatibility

Designed as a direct OEM replacement for the ICP-family RGX048KRCA0AAA, also sold by Heil, Tempstar, and Comfortmaker under International Comfort Products. Confirm the 40A rating, 2-pole configuration, and 24V coil against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter on both line terminals.
  2. Access — Remove the electrical/service panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and torque the lugs snug.
  6. Test — Restore power, call for cooling/operation, and confirm a clean, silent pull-in with no chatter.

Signs You Need a Replacement

  • Buzzing or chattering contactor that won't pull in cleanly.
  • Pitted, burnt, or welded contacts that stick closed.
  • System won't start even though the 24V coil is being energized.
  • Visible arcing, melted housing, or carbon tracking on the terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGX048KRCA0AAA — OEM Part 1176763 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGX048KRCA0AAA — OEM Part 1176763 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGX048KRCA0AAA — OEM Part 1176763 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.