This OEM ICP contactor (part number 1176763) is the 40-amp, 2-pole electrical switch that energizes the compressor and condenser fan motor in your ICP/Tempstar/Heil WCH3614GKC110 heat pump. When the thermostat calls for cooling or heating, the 24V control coil pulls in the contactor, closing the line-voltage contacts that power the outdoor unit. Years of cycling pit, arc, and burn the contacts — a failing contactor is one of the most common reasons an outdoor unit hums but won't start, chatters, or sticks closed and runs continuously. Replacing it restores clean, reliable switching.

Specifications

Spec Value
Part Number 1176763
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Rating 40 Amp
Poles 2-Pole
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WCH3614GKC110 heat pump condenser. The 40A 2-pole, 24V-coil format is also common across many comparable 3-ton ICP-family outdoor units — always confirm amperage, pole count, and coil voltage against the contactor you are removing before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Note line, load, and 24V coil terminals, transfer wires one at a time, and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and verify the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor and fan won't start
  • Visible pitting, burning, or melted plastic on the contacts
  • Chattering or rapid clicking when the system calls for cooling
  • Contacts stick closed and the unit runs nonstop

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3614GKC110 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3614GKC110 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3614GKC110 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online