Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 30A 2-Pole / 40A 3-Pole 24V Contactor Set for RGS213HSEA0AAAA | Ships Today
ICP

ICP 30A 2-Pole / 40A 3-Pole 24V Contactor Set for RGS213HSEA0AAAA | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM contactor set for ICP / Tempstar / Heil RGS213HSEA0AAAA systems, covering both the 2-pole 30-amp contactor (part number 1171554) and the 3-pole 40-amp contactor (part number 1172449), each with a 24V control coil. A contactor is the high-current switch that powers the compressor and condenser fan motor. When the thermostat sends a 24V signal to the coil, the contactor pulls in and closes its line-voltage contacts to start the outdoor unit. Worn, pitted, or stuck contactor contacts are one of the most common no-cooling failures, often showing up as a buzzing outdoor unit or a system that won't start even with a valid cooling call.

Specifications

Spec Value
Part Number (2-Pole) 1171554 — Contactor 2P 30A 24V
Part Number (3-Pole) 1172449 — Contactor 3P 40A 24V
Coil Voltage 24V
Rating 30A (2-pole) / 40A (3-pole)
Poles 2-Pole and 3-Pole
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Fits ICP, Tempstar, and Heil RGS213HSEA0AAAA systems and related chassis. Confirm your required pole count and amp rating against the contactor currently installed before ordering, as the correct unit depends on your specific outdoor model and electrical load.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit control panel cover.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Unbolt the old contactor and transfer wires one terminal at a time.
  5. Install — Mount the new contactor and reconnect each wire per your photo, matching the 24V coil leads.
  6. Test — Restore power, send a cooling call, and confirm the contactor pulls in and the unit starts.

Signs You Need a Replacement

  • Buzzing or chattering outdoor unit that won't start
  • Pitted, burned, or welded contacts
  • Compressor and fan that run continuously even after the call ends
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213HSEA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213HSEA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213HSEA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart