Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 3-Pole 30A Contactor for RYMA10N001A — 24V Coil | Ships Today
ICP

ICP 3-Pole 30A Contactor for RYMA10N001A — 24V Coil | Ships Today

SKU: 1050699-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor switches high-voltage power to the compressor and condenser fan motor in your ICP / Heil / Tempstar RYMA10N001A heat pump. When the thermostat calls, the 24V coil pulls the contacts closed to energize the outdoor unit. Available configurations for this platform include a 1-pole 25A (OEM 1050699), 2-pole 20A (OEM 1054735), and 3-pole 30A (OEM 1070823 and 607339) — all with a 24-volt coil. A worn contactor is one of the most common no-cool/no-heat callbacks: pitted or welded contacts, a chattering or open coil, or a buzzing relay all point to replacement. Symptoms include the outdoor unit not starting, contacts that stick closed (unit won't shut off), or visible arcing and burnt terminals.

Specifications

Spec Value
Part Numbers 1050699, 1054735, 1070823, 607339
Type Definite-Purpose Contactor
Brand ICP (Heil / Tempstar)
Poles 1-Pole / 2-Pole / 3-Pole
Rating 20A / 25A / 30A
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Designed for the ICP / Heil / Tempstar / Comfortmaker RYMA10N001A heat pump and related models using the same outdoor control wiring. Match the pole count and amp rating on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter across all line terminals.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit won't start on a thermostat call
  • Loud humming, buzzing, or chattering from the contactor
  • Pitted, burnt, or welded contacts (unit won't turn off)
  • Visible arcing or melted terminal insulation

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RYMA10N001A — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RYMA10N001A — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RYMA10N001A — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online