This is a genuine OEM 3-pole definite purpose contactor (part number 14303002) for the ICP/Heil/Tempstar YE036F heat pump system. The contactor is the high-voltage relay that switches power to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heating. Rated at 25 amps per pole with a 24-volt coil, it makes and breaks line voltage thousands of times per season. When a contactor fails, you'll typically see pitted or welded contacts, a humming or chattering sound, or an outdoor unit that won't start even though the thermostat is calling — all signs the contacts are no longer making clean connection.

Specifications

Spec Value
Part Number 14303002
Type Definite Purpose Contactor, 3-Pole
Brand ICP / Heil / Tempstar
Contact Rating 25 Amps
Coil Voltage 24V
Poles 3

Compatibility

Designed as the factory replacement for the ICP/Heil/Tempstar YE036F condensing unit and other ICP-family heat pumps and air conditioners using a 3-pole 25A 24V contactor. Always confirm the part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel on the condensing unit.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Note line and load wiring and the two 24V coil leads, then unfasten the old contactor from its mounting bracket and transfer wires one at a time.
  5. Install — Mount the new contactor, reconnect line, load, and coil wires exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan energize.

Signs You Need a Replacement

  • Loud humming, buzzing, or chattering from the outdoor unit
  • Burned, pitted, or welded contacts visible on the old part
  • Compressor and condenser fan fail to start on a cooling call
  • Contacts that stick closed and won't release when the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YE036F — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YE036F — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YE036F — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online