Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 3-Pole 25A Contactor for YC060H — 24V Coil | Ships Today
ICP

ICP 3-Pole 25A Contactor for YC060H — 24V Coil | Ships Today

SKU: 14303002 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 3-pole definite-purpose contactor (ICP part #14303002) is the primary switching relay for the outdoor condensing unit on your ICP/Tempstar/Heil YC060H heat pump. Rated at 25 amps per pole with a 24-volt coil, it energizes the compressor and condenser fan motor each time the thermostat calls for cooling or heating. When the low-voltage coil is energized, the three sets of silver-cadmium contacts pull in and pass line voltage to the high-amp loads. Over thousands of cycles these contacts pit, burn, and weld — the most common cause of a unit that hums but won't start, won't shut off, or trips the breaker. Replacing a worn contactor is one of the cheapest ways to protect a far more expensive compressor.

Specifications

Spec Value
Part Number 14303002
Type 3-Pole Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Contact Rating 25 Amps per pole
Coil Voltage 24V
Poles 3
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM fit for the ICP/Tempstar/Heil YC060H heat pump and related condensing units sharing this electrical platform. Always confirm your existing contactor is a 3-pole, 25A, 24V-coil unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect each wire, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call and drops out on satisfy.

Signs You Need a Replacement

  • Compressor hums or buzzes but the unit won't start
  • Burned, pitted, or welded contacts (unit won't shut off)
  • Chattering or rapid clicking from the contactor
  • Visible arcing, melted housing, or a burnt-electrical smell

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YC060H — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YC060H — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YC060H — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online