Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 3-Pole 25A Contactor for YC048F — 24V Coil | Ships Today
ICP

ICP 3-Pole 25A Contactor for YC048F — 24V Coil | Ships Today

SKU: 14303002-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM definite-purpose contactor (part number 14303002) for the ICP / Tempstar / Heil YC048F heat pump. A contactor is the high-voltage switch that energizes the compressor and condenser fan motor whenever the 24V control circuit calls for cooling or heating. This is a 3-pole, 25 amp unit with a 24-volt coil. When the contactor fails, the outdoor unit will either stop running entirely or buzz, chatter, and weld its contacts shut so the system runs continuously. Pitted, burned, or stuck contacts are one of the most common causes of an outdoor unit that won't start.

Specifications

Spec Value
Part Number 14303002
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 3-Pole
Contact Rating 25 Amps
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP, Tempstar, and Heil YC048F and other equipment using OEM contactor 14303002. Always confirm the existing contactor's pole count, amp rating, and 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting anything.
  4. Remove — Label and disconnect the wires, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm the 24V coil leads are landed.
  6. Test — Restore power and verify the contactor pulls in cleanly and the compressor and fan energize on a call.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor won't start.
  • Visibly pitted, burned, or melted contacts.
  • Contacts stick closed so the unit runs nonstop.
  • Loud chattering or rapid clicking when the thermostat calls.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YC048F — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YC048F — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YC048F — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online