OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 3-pole, 25-amp contactor (ICP part 14303002) is the electrical switch that delivers line voltage to the compressor and condenser fan in your YC036F. When the thermostat calls, the 24V coil pulls the three sets of contacts closed; when the call ends, springs open them. Over thousands of cycles the silver contacts pit, burn, and weld, and the 24V coil can fail open. The result is a unit that won't start, hums without engaging, or — when contacts weld — runs continuously. Replacing a worn contactor is one of the most common, lowest-cost HVAC repairs.
| Spec | Value |
|---|---|
| Part Number | 14303002 |
| Type | 3-Pole Definite Purpose Contactor |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Contact Rating | 25 Amp |
| Coil Voltage | 24V |
| Poles | 3 |
| Fit | OEM Replacement |
Direct OEM replacement for the ICP YC036F and other Tempstar, Heil, and Comfortmaker condensing units that shipped with the 25A 24V contactor 14303002. Confirm pole count, amp rating, and 24V coil match your existing part before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.