This genuine OEM 3-pole, 25-amp definite purpose contactor (part number 14303002) with a 24-volt coil is the primary power switch for the outdoor unit on ICP, Heil, and Tempstar YA060H systems. When the thermostat calls for cooling or heat pump operation, the 24VAC coil pulls in the contactor, closing all three poles to deliver line voltage to the compressor and condenser fan motor. Contactors are high-cycle parts whose contacts pit, arc, and weld over thousands of operations. A failing contactor causes hard starts, chattering, buzzing, intermittent cooling, or a unit that won't shut off because the contacts have fused closed.
| Spec | Value |
|---|---|
| Part Number | 14303002 |
| Type | Definite Purpose Contactor |
| Brand | ICP / Heil / Tempstar |
| Poles | 3-Pole |
| Contact Rating | 25 Amps |
| Coil Voltage | 24 VAC |
| Fitment | OEM Replacement |
Direct OEM replacement for the ICP/Heil/Tempstar YA060H condensing unit and other ICP-family units specifying a 3-pole, 25A, 24V-coil contactor. Confirm pole count (3), amp rating (25A), and 24V coil against your existing part before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.