Overview

The L01H009 is a genuine OEM 24VAC control relay (AG90-23242-024W) used in the low-voltage control circuit of the ICP / Tempstar / Heil SUP23M2301CIA. The relay uses a 24-volt coil to switch line-voltage loads such as the blower, inducer, or auxiliary components on a call from the thermostat or control board. When this relay fails, the system may not respond to thermostat calls, components may chatter, or a load may stay energized or refuse to start. Replacing it with the exact OEM part restores correct sequencing and protects the rest of the control circuit.

Specifications

Spec Value
Part Number L01H009
OEM Reference AG90-23242-024W
Type Control Relay
Coil Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fits Model SUP23M2301CIA

Compatibility

Engineered for the ICP-family SUP23M2301CIA and shared across many ICP, Tempstar, Heil, and Comfortmaker air handlers and furnaces using the same 24VAC control platform. Verify your unit's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the service / control panel to expose the low-voltage board.
  3. Document — Photograph all relay wiring before disconnecting.
  4. Remove — Label and pull the spade connectors, then unclip or unscrew the failed relay.
  5. Install — Mount the new L01H009 and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the relay pulls in and switches its load on a thermostat call.

Signs You Need a Replacement

  • System ignores thermostat calls or responds intermittently.
  • Audible chatter or buzzing from the control area.
  • Blower or component stays running or won't start.
  • Burnt, pitted, or welded relay contacts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP SUP23M2301CIA — OEM L01H009 | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP SUP23M2301CIA — OEM L01H009 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP SUP23M2301CIA — OEM L01H009 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.