Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 24V Transformer for YH024GC — 40VA Heat Pump Control | Ships Today
ICP

ICP 24V Transformer for YH024GC — 40VA Heat Pump Control | Ships Today

SKU: 34329055-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 24-volt control transformer powers the low-voltage circuit on the ICP YH024GC heat pump, supplying the 24V the system needs to energize its reversing valve coil (part 34329055), control relays (parts 96467 and 1053004), contactor, and thermostat. The transformer steps line voltage down to 24VAC at roughly 40VA of capacity. A failed transformer is a leading no-heat / no-cool cause: when it opens or shorts, the whole control circuit goes dead and nothing energizes even with line power present.

Specifications

Spec Value
Type Step-Down Control Transformer
Secondary Output 24V
Rating 40VA
Brand ICP / Heil / Tempstar
Associated Parts 34329055 (Rev. Valve Coil 24V), 96467 (Relay 24V), 1053004 (Relay 24V)
Application Heat Pump Control Circuit

Compatibility

Fits the ICP/Heil/Tempstar/Comfortmaker YH024GC heat pump and related control assemblies that use a 24V, 40VA transformer to drive the reversing-valve coil and control relays. Verify your original transformer's VA rating and lead configuration before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control box.
  3. Document — Photograph all primary and secondary leads before disconnecting.
  4. Remove — Disconnect the line-voltage primary and 24V secondary leads and unbolt the old transformer.
  5. Install — Mount the new transformer, reconnect primary to line voltage and secondary to the 24V circuit per your photo.
  6. Test — Restore power and confirm 24VAC across the secondary and that relays and the reversing valve coil energize.

Signs You Need a Replacement

  • No 24V at the thermostat or control board — entire low-voltage circuit dead.
  • Blown control fuse that re-blows immediately (shorted secondary).
  • Buzzing, overheating, or burnt-smelling transformer.
  • Relays and reversing-valve coil won't pull in despite line power present.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP YH024GC — 40VA Heat Pump Control | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP YH024GC — 40VA Heat Pump Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP YH024GC — 40VA Heat Pump Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.