Overview

This OEM 24-volt control transformer supplies the low-voltage power that runs the control circuit on your ICP Tempstar Heil WCH3364GKA2 heat pump. It steps line voltage down to a stable 24V to energize the contactor coil, reversing valve solenoid (parts 1172574 / 1175621), and thermostat circuit. Rated at 40VA, it provides the steady control current the system needs to switch reliably between heating and cooling. When a transformer fails — open winding, shorted turns, or a tripped internal fuse — the entire 24V control side goes dead: the thermostat blanks, the contactor never pulls in, and the outdoor unit will not respond to a call.

Specifications

Spec Value
OEM Part Numbers 1172574 (Coil Rev Vlv 24V), 1175621 (Valve Rev w/Coil 24V)
Type 24V Step-Down Control Transformer
Brand ICP / Tempstar / Heil / Comfortmaker
Secondary Voltage 24V
Rating 40VA
Fitment OEM Replacement

Compatibility

Direct OEM low-voltage control replacement for the ICP/Tempstar/Heil/Comfortmaker WCH3364GKA2 heat pump. Confirm your existing component's secondary voltage (24V) and VA rating before installing, and match the wiring leads to your unit's control schematic.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and main breaker. Verify zero voltage with a multimeter on both the line and 24V sides.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph all primary and secondary leads before disconnecting.
  4. Remove — Disconnect the line-voltage primary and 24V secondary leads, then unmount the old component.
  5. Install — Mount the new part and reconnect each lead exactly per your photo, keeping line and low-voltage sides separate.
  6. Test — Restore power, confirm 24V at the secondary with a meter, and verify the contactor and reversing valve energize on a call.

Signs You Need a Replacement

  • Dead or blank thermostat with no 24V control power
  • Contactor never pulls in despite a valid call
  • Reversing valve fails to shift between heat and cool
  • Burned smell or visibly scorched windings at the control component

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my ICP WCH3364GKA2 — 40VA Control Power | Ships Today?
Yes. This is the factory-specified OEM transformer for the ICP WCH3364GKA2 — 40VA Control Power | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my ICP WCH3364GKA2 — 40VA Control Power | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.