This OEM 24-volt control transformer supplies the low-voltage power that runs the ICP WCH3314GKC100 heat pump's control circuit (associated OEM parts #1172574 and #1175621). It steps line voltage down to a stable 24 VAC at roughly 40VA to energize the contactor coil, defrost board, reversing-valve coil, and thermostat circuit. Every low-voltage component in the system depends on it. When a transformer fails — usually from a shorted secondary, an overloaded control circuit, or age — the unit goes completely unresponsive: no contactor pull-in, a dead thermostat, and no 24V at the board. A burnt-smelling or visibly bulged transformer is a clear sign of failure. It's an inexpensive part whose loss takes the whole system offline, making it a fast, high-value repair.
| Spec | Value |
|---|---|
| Part Numbers | 1172574, 1175621 |
| Type | Control Transformer |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Secondary Voltage | 24 VAC |
| Rating | 40 VA |
| Application | Heat Pump control circuit |
Direct OEM fit for the ICP/Tempstar/Heil WCH3314GKC100 heat pump and matching ICP-family units using a 24V/40VA control transformer. Always confirm primary and secondary voltage and VA rating against your existing transformer before installing.